Re: Image capture error
Using FD worked for me but don't hit validate because it will convert the template back to the default settings
View ArticleRe: Image capture error
i have rebuilt my server and it works now with no issues or extra commands just the write filter bit doesnt work.
View ArticleRe: Multiple PXE Representatives in environment booting up with same error...
All right - marking SP1 as the answer to this issue. Thanks for the confirmation .
View ArticleRe: Unable to add Bare Metal Servers on Remote Consoles LDMS96
Hi Wade, I haven't updated to SP1 yet. There is a section under the "inventory9_6sp1_docx" readme for changes to Inventory in SP1 so I assume the problem I was experiencing has been fixed. ill update...
View ArticleRe: Unable to add Bare Metal Servers on Remote Consoles LDMS96
FYI.The issue is not resolved in SP1. Only local group "LANDESK Administrators" have full control on ldlogon folder.As a workaround you can add write rights to local group "LANDesk Management Suite" on...
View ArticleRe: Unable to add Bare Metal Servers on Remote Consoles LDMS96
We upgraded to SP1 a few weeks ago, and our techs are now able to add bare metal systems from the remote console without a problem.
View ArticleRe: Unable to add Bare Metal Servers on Remote Consoles LDMS96
Hi Steve, We are definitely still having this issue with SP1. What roles do your techs have? We used the workaround Amagi mentioned with the addition of adding "change" rights to the ldlogon share....
View ArticleRe: The feared CTOS..
Could you share your workaround? I've got a system that's exhibiting this same behavior...
View ArticleNew Landesk User - PC not booting into sysprep process
Hi all, I am a new LANDESK user (currently in the trial), and I need a bit of help/advice regarding OS Provisioning. I have built a template which successfully deploys the image and inject's the...
View ArticleRe: New Landesk User - PC not booting into sysprep process
Ok, I think I was missing something obvious. I had failed to launch sysprep on the PC before capturing the image. After recapturing the (syspreped) image I have got a bit further. Now when my deploy...
View ArticleRe: New Landesk User - PC not booting into sysprep process
I would boot the client back into WinPE and manually verify your unattend.xml has the correct password being shown once written to the client. Below is the Audit section from my answer file with the...
View ArticleRe: Unattend getting truncated after generalize pass
You have to be "bandaiding" something. We Provisioned hundreds of machines in 5 sites over three states on 9.5 SP2 and have never had to inject wait states. While I am certain that you have a problem,...
View ArticleRe: Unattend getting truncated after generalize pass
Joe, While I can see that what you said in a prior post could cause issues with the provisioning process, the only one that seemed as though it could cause the unattend truncation error was joining the...
View ArticleRe: Unattend getting truncated after generalize pass
I have to agree that this is something INSIDE of Windows Setup/Sysprep. The customer I support just introduced a new model into their environment. This model experiences the same problems with the...
View ArticleRe: Unattend getting truncated after generalize pass
I concede then, that the problem is not only real, but that based upon the discussion that many have presented, the problem may be my own the next time we move to a new model Lenovo! With that thought...
View ArticleRe: Unattend getting truncated after generalize pass
Joe, I'm not ready to pin the blame on UEFI yet. I've had it happen when I was doing a straight BIOS based image. I believe the PXE rep should determine which WinPE wim you will need based on the...
View ArticleRe: LANDesk 9.6 SP1 Provisioning Custom Messages issue
OK it does not seem this is possible via what I assumed is the simple way. Provisioning tasks seem to be "PUSH" only run but I don't understand what push methods they use as it did not seem to matter...
View ArticleProblem with executing file in Provisioning task showing in Interactive...
I have a provisioning task which copies and runs a *.hta file that displays a message to the user on what is happening and has a proceed button on one and a finish button on another. The task starts OK...
View Article9.6 SP1 - Provision OS use multicast
I am having trouble getting multicast imaging to work in 9.6 SP1. I get two different results. I have two different templates that have the same exact steps, each has a slightly different outcome. 1....
View ArticleRe: pxe tftp: No slot is empty to process this client's request
I found out . create new REG_SZ value named : Max_Transfers Under HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Intel\PXE\Mtftpdand set the number to what you want , i sat it to 200.